Warning: include(http://klahost.com/floating-banner/melbourne.php): failed to open stream: HTTP request failed! HTTP/1.1 404 Not Found in /home/hebelpan/public_html/wp-content/themes/suffusion/header.php on line 63

Warning: include(): Failed opening 'http://klahost.com/floating-banner/melbourne.php' for inclusion (include_path='.:/opt/php54/lib/php') in /home/hebelpan/public_html/wp-content/themes/suffusion/header.php on line 63
Jun 282012
 

A.1 Manufacturing Tolerances

 

Length ±5mm
Width ±1.5mm
Thickness ±1.5mm
Diagonals (Max.) 5mm
Edge Straightness
Deviation (Max.)
1.5mm

 

A.2 PowerPanel Physical Properties

 

  • Hebel PowerPanel profile and nominal dimensions are shown in Section 13.0.
  • Panel reinforcement is a single layer of steel mesh with 4 longitudinal wires of 4mm diameter.
  • Nominal dry density = 510 kg/m3.
  • Average working density = 663 kg/m3 at 30% moisture content.
  • Average service life density = 561 kg/m3 at 10% moisture content.

 

A.3 PowerPanel Strength Properties

 

  • Characteristic Compressive Strength or AAC, f ’m= 2.8 MPa.
  • Average Compressive Strength of AAC = 4.0 MPa.
  • Characteristic Modulus of Rupture, f ’ut = 0.60 MPa.

A.4 PowerPanel Acoustic Properties

 

  • Panel only with no plasterboard or other lining Rw = 36dB, Rw+Ctr = 33dB (refer to acoustic test ATF-676).

 

A.5 PowerPanel Thermal Properties

 

  • R-Value of PowerPanel with no plasterboard or other lining = 0.51 m2.K/W (4% moisture content).

 

A.6 Fire Hazard Indices

 

Hebel products have BCA Group Number 1 and also the following early fire hazard indices, determined in accordance with AS1530.3:1990:

 

Ignitability Index 0
Spread of Flame Index 0
Heat Development Index 0
Smoke Development Index 0-1

A.7 Fire Resistance Level (FRL) Ratings

 

For fire performance characteristics of Hebel PowerWall, refer to Section 7.0 of this guide.

 